|
|
||||||||
Brief Communication |
Plant Biomechanics Group, University of Freiburg, Schaenzlestr.1, D-79104 Freiburg, Germany
Received for publication December 11, 2003. Accepted for publication May 28, 2004.
| ABSTRACT |
|---|
|
|
|---|
Key Words: endodermis Equisetum mechanical tests turgor pressure
| INTRODUCTION |
|---|
|
|
|---|
This hypothesis was tested in two ways. First, as direct proof, samples treated by cutting the endodermis of Equisetum hyemale longitudinally were subjected to transverse compression in different orientations. Second, we tested the dependence of transverse stability on turgor pressure by comparing eight different species of Equisetum having either two or one continuous layers of endodermis or an endodermis surrounding only the vascular bundles. Cross-sections of Equisetaceae have been described before (Bold, 1973
; Spatz et al., 1998
; Speck et al., 1998
). The phylogenetic relations have been elucidated by Des Marais et al. (2003)
.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Cross-sections from various parts of the plant stems were cut with a scalpel and stained with phloroglucinol-HCl as described by Gerlach (1984)
.
Dissection of the endodermis
Small cylindrical segments (ca. 6 mm long) of Equisetum hyemale were prepared, and the endodermis was cut longitudinally under a stereomicroscope with a specially prepared razor blade. Two cuts were made across from one another, such that each went from the inside of the hollow cylinder into a vallecular canal. As a control the parenchyma in segments of E. giganteum was cut in the same way.
Turgor pressure was reduced by submersing segments (15 mm long cylinders unless otherwise stated) in solutions of polyethyleneglycol (PEG 6000, Roth, Karlsruhe, Germany) of 10 bar osmolality for 15 h (Schopfer, 1986
). Care was taken to replace air in the pith cavity with the PEG solution. A control segment from the same internode was placed in H2O for the same duration.
Transverse compression has been described in more detail (Spatz et al., 1995
, 1996
). In short, the cylindrical segments prepared from internodes at various positions along the length of the stem were subjected to mechanical testing (Fig. 1): displacement and forces to deform the segment with a cross-section approximating a circular ring to an elliptical ring shape were measured in an Instron Universal Testing Machine, Model 4466 (Instron Wolpert, Ludwigshafen, Germany). Samples in which the endodermis was dissected longitudinally were oriented in such a way that the cuts were at 0° and 180°, that is, in the direction of the force applied, or at 90° and 270° angles to the applied force.
|
|
| RESULTS AND DISCUSSION |
|---|
|
|
|---|
|
Dependence on turgor pressure
Exposure to PEG solutions only slightly reduced the transverse compressibility of Equisetum hyemale (Table 1). This can have two reasons: water does not diffuse efficiently from the tissues into the PEG solution, or it is a manifestation of an inherent property of the structure. Two experiments were done to rule out the first possibility. (1) Differently sized (between 3 and 20 mm) matched pairs of segments were exposed to either PEG solutions or H2O. The length of the segments did not affect the ratio of the mechanical stabilities in transverse compression. (2) Prior to the 15-h exposure of segments (3 mm or 6 mm long) to the PEG solution, the vallecular canals were filled directly with a syringe with this solution. Again, no significant difference from the usual exposure to PEG solutions was found.
Comparison with other Equisetum species
The size of the stems of Equisetum affinis, a hybrid between E. hyemale and, presumably, E. giganteum, are much larger, but the cross-sections are very similar to E. hyemale. Like the latter, Equisetum affinis has two continuous layers of endodermis. Its susceptibility to reduction of turgor pressure is not significantly different from that in Equisetum hyemale (Table 1). Equisetum telmateja, with only one continuous layer of endodermis has a higher susceptibility compared to E. affinis (P < 0.01) as well as to E. hyemale (P < 0.001).
An even higher susceptibility is expected if only the vascular bundles are surrounded by endodermis. Figure 2 shows a comparison of force-deflection curves in transverse compression of matched Equisetum giganteum segments after PEG or H2O treatment. The mechanical behavior is quite different for the two samples. The slopes of the curves differ approximately by a factor of 4. The average for stems younger than 1 yr, listed in Table 1, confirms earlier data (Spatz et al., 1998
). Older stems are less susceptible to a reduction of turgor pressure. Ratios approximating 2 are found.
Large standard deviations are found for Equisetum fluviatile both for stem parts above water level and for submersed parts of the stem. The reason for this biological variation is not yet known. Even with this caveat, it is clear that Equisetum fluviatile is quite susceptible to a reduction of turgor pressure.
The smaller species, Equisetum arvense, E. sylvaticum, and E. pratense, fall into a different class. Although only one continuous layer of endodermis is present, exposure to PEG reduces the mechanical stability only marginally. Even on a relative scale, the pith cavities are so small that a single layer of strengthening tissue will have a substantial stabilizing effect at least under conditions of low turgor pressure.
| FOOTNOTES |
|---|
2 E-mail: spatz{at}biologie.uni-freiburg.de ![]()
| LITERATURE CITED |
|---|
|
|
|---|
Brazier L. G. 1927 On the flexure of thin cylindrical shells and other "thin" sections. Proceedings of the Royal Society of London, A 116: 104-114[CrossRef]
Des Marias D. L. A. R. Smith D. M. Britton K. M. Pryer 2003 Phylogenetic relationships and evolution of extant horsetails, Equisetum, based on chloroplast DNA sequence data (rbcL and trnL-F). International Journal of Plant Science 164: 737-751[CrossRef]
Gerlach D. 1984 Botanische Mikrotechnik, 3rd ed. Thieme Verlag, Stuttgart, Germany
Niklas K. J. 1989 Extracellular freezing in Equisetum hyemale. American Journal of Botany 76: 627-631[CrossRef][ISI]
Schopfer P. 1986 Experimentelle Pflanzenphysiologie. Bd. 1Einführung in die Methoden. Springer Verlag, Berlin, Germany
Spatz H.-CH. H. Beismann F. Brüchert A. Emanns T. Speck 1997 Biomechanics of the giant reed Arundo donax. Philosophical Transactions of the Royal Society of London, B 352: 1-10[CrossRef]
Spatz H.-CH. H. Beismann A. Emanns T. Speck 1995 Mechanical anisotropy and inhomogeneity in the tissues comprising the hollow stem of the giant reed Arundo donax. Biomimetics 3: 141-155
Spatz H.-CH. H. Beismann A. Emanns T. Speck 1996 A new method to determine Young's modulus in tangential direction for hollow tubes, in particular hollow plant stems. Proceedings of the Third Biennial ESDA Conference, Montpellier 77: 221-224
Spatz H.-CH. L. Köhler T. Speck 1998 Biomechanics and functional anatomy of hollow stemmed sphenopsids: I. Equisetum giganteum (Equisetaceae). American Journal of Botany 85: 305-314[Abstract]
Speck T. O. Speck A. Emanns H.-CH. Spatz 1998 Biomechanics and functional anatomy of hollow stemmed sphenopsids. III. Equisetum hyemale. Botanica Acta 111: 366-376[ISI]
Von Karman T. 1911 Über die Formänderung dünnwandiger Rohre, insbesondere federnder Ausgleichsrohre. Zeitschrift der Vereinigung deutscher Ingenieure 55: 1889-1895
This article has been cited by other articles:
![]() |
M. Milwich, T. Speck, O. Speck, T. Stegmaier, and H. Planck Biomimetics and technical textiles: solving engineering problems with the help of nature's wisdom Am. J. Botany, October 1, 2006; 93(10): 1455 - 1465. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |